Remove sftp-PR as its too specific

This commit is contained in:
Daniel Berteaud 2024-04-17 23:30:12 +02:00
parent 3ae75ce54f
commit ea1dc23cbb
2 changed files with 357 additions and 356 deletions

View File

@ -829,361 +829,6 @@ _EOT
left_delimiter = "{{{"
right_delimiter = "}}}"
}
template {
data = <<_EOT
groups:
- name: NodeExporter
rules:
- alert: HostOutOfMemory
expr: '(node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host out of memory (instance {{ $labels.instance }})
description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostMemoryUnderMemoryPressure
expr: '(rate(node_vmstat_pgmajfault[1m]) > 1000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host memory under memory pressure (instance {{ $labels.instance }})
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostMemoryIsUnderutilized
expr: '(100 - (avg_over_time(node_memory_MemAvailable_bytes[30m]) / node_memory_MemTotal_bytes * 100) < 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 1w
labels:
severity: info
annotations:
summary: Host Memory is underutilized (instance {{ $labels.instance }})
description: "Node memory is < 20% for 1 week. Consider reducing memory space. (instance {{ $labels.instance }})\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualNetworkThroughputIn
expr: '(sum by (instance) (rate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual network throughput in (instance {{ $labels.instance }})
description: "Host network interfaces are probably receiving too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualNetworkThroughputOut
expr: '(sum by (instance) (rate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual network throughput out (instance {{ $labels.instance }})
description: "Host network interfaces are probably sending too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskReadRate
expr: '(sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual disk read rate (instance {{ $labels.instance }})
description: "Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskWriteRate
expr: '(sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write rate (instance {{ $labels.instance }})
description: "Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOutOfDiskSpace
expr: '((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host out of disk space (instance {{ $labels.instance }})
description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostDiskWillFillIn24Hours
expr: '((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host disk will fill in 24 hours (instance {{ $labels.instance }})
description: "Filesystem is predicted to run out of space within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOutOfInodes
expr: '(node_filesystem_files_free{fstype!="msdosfs"} / node_filesystem_files{fstype!="msdosfs"} * 100 < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host out of inodes (instance {{ $labels.instance }})
description: "Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostFilesystemDeviceError
expr: 'node_filesystem_device_error == 1'
for: 0m
labels:
severity: critical
annotations:
summary: Host filesystem device error (instance {{ $labels.instance }})
description: "{{ $labels.instance }}: Device error with the {{ $labels.mountpoint }} filesystem\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostInodesWillFillIn24Hours
expr: '(node_filesystem_files_free{fstype!="msdosfs"} / node_filesystem_files{fstype!="msdosfs"} * 100 < 10 and predict_linear(node_filesystem_files_free{fstype!="msdosfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly{fstype!="msdosfs"} == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host inodes will fill in 24 hours (instance {{ $labels.instance }})
description: "Filesystem is predicted to run out of inodes within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskReadLatency
expr: '(rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk read latency (instance {{ $labels.instance }})
description: "Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskWriteLatency
expr: '(rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 0.1 and rate(node_disk_writes_completed_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write latency (instance {{ $labels.instance }})
description: "Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostHighCpuLoad
expr: '(sum by (instance) (avg by (mode, instance) (rate(node_cpu_seconds_total{mode!="idle"}[2m]))) > 0.8) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 10m
labels:
severity: warning
annotations:
summary: Host high CPU load (instance {{ $labels.instance }})
description: "CPU load is > 80%\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# - alert: HostCpuIsUnderutilized
# expr: '(100 - (rate(node_cpu_seconds_total{mode="idle"}[30m]) * 100) < 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
# for: 1w
# labels:
# severity: info
# annotations:
# summary: Host CPU is underutilized (instance {{ $labels.instance }})
# description: "CPU load is < 20% for 1 week. Consider reducing the number of CPUs.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostCpuStealNoisyNeighbor
expr: '(avg by(instance) (rate(node_cpu_seconds_total{mode="steal"}[5m])) * 100 > 10) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host CPU steal noisy neighbor (instance {{ $labels.instance }})
description: "CPU steal is > 10%. A noisy neighbor is killing VM performances or a spot instance may be out of credit.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostCpuHighIowait
expr: '(avg by (instance) (rate(node_cpu_seconds_total{mode="iowait"}[5m])) * 100 > 10) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host CPU high iowait (instance {{ $labels.instance }})
description: "CPU iowait > 10%. A high iowait means that you are disk or network bound.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskIo
expr: '(rate(node_disk_io_time_seconds_total[1m]) > 0.5) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual disk IO (instance {{ $labels.instance }})
description: "Time spent in IO is too high on {{ $labels.instance }}. Check storage for issues.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostContextSwitching
expr: '((rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 20000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host context switching (instance {{ $labels.instance }})
description: "Context switching is growing on the node (> 20000 / CPU / s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# - alert: HostSwapIsFillingUp
# expr: '((1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
# for: 2m
# labels:
# severity: warning
# annotations:
# summary: Host swap is filling up (instance {{ $labels.instance }})
# description: "Swap is filling up (>80%)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostSystemdServiceCrashed
expr: '(node_systemd_unit_state{state="failed"} == 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host systemd service crashed (instance {{ $labels.instance }})
description: "systemd service crashed\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostPhysicalComponentTooHot
expr: '((node_hwmon_temp_celsius * ignoring(label) group_left(instance, job, node, sensor) node_hwmon_sensor_label{label!="tctl"} > 75)) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host physical component too hot (instance {{ $labels.instance }})
description: "Physical hardware component too hot\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNodeOvertemperatureAlarm
expr: '(node_hwmon_temp_crit_alarm_celsius == 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: critical
annotations:
summary: Host node overtemperature alarm (instance {{ $labels.instance }})
description: "Physical node temperature alarm triggered\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRaidArrayGotInactive
expr: '(node_md_state{state="inactive"} > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: critical
annotations:
summary: Host RAID array got inactive (instance {{ $labels.instance }})
description: "RAID array {{ $labels.device }} is in a degraded state due to one or more disk failures. The number of spare drives is insufficient to fix the issue automatically.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRaidDiskFailure
expr: '(node_md_disks{state="failed"} > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host RAID disk failure (instance {{ $labels.instance }})
description: "At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostKernelVersionDeviations
expr: '(count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 6h
labels:
severity: warning
annotations:
summary: Host kernel version deviations (instance {{ $labels.instance }})
description: "Different kernel versions are running\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOomKillDetected
expr: '(increase(node_vmstat_oom_kill[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host OOM kill detected (instance {{ $labels.instance }})
description: "OOM kill detected\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacCorrectableErrorsDetected
expr: '(increase(node_edac_correctable_errors_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: info
annotations:
summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacUncorrectableErrorsDetected
expr: '(node_edac_uncorrectable_errors_total > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkReceiveErrors
expr: '(rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Receive Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} receive errors in the last two minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkTransmitErrors
expr: '(rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Transmit Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} transmit errors in the last two minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkInterfaceSaturated
expr: '((rate(node_network_receive_bytes_total{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"}[1m]) + rate(node_network_transmit_bytes_total{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"}[1m])) / node_network_speed_bytes{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"} > 0.8 < 10000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 1m
labels:
severity: warning
annotations:
summary: Host Network Interface Saturated (instance {{ $labels.instance }})
description: "The network interface \"{{ $labels.device }}\" on \"{{ $labels.instance }}\" is getting overloaded.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkBondDegraded
expr: '((node_bonding_active - node_bonding_slaves) != 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Bond Degraded (instance {{ $labels.instance }})
description: "Bond \"{{ $labels.device }}\" degraded on \"{{ $labels.instance }}\".\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostConntrackLimit
expr: '(node_nf_conntrack_entries / node_nf_conntrack_entries_limit > 0.8) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host conntrack limit (instance {{ $labels.instance }})
description: "The number of conntrack is approaching limit\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostClockSkew
expr: '((node_timex_offset_seconds > 0.05 and deriv(node_timex_offset_seconds[5m]) >= 0) or (node_timex_offset_seconds < -0.05 and deriv(node_timex_offset_seconds[5m]) <= 0)) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 10m
labels:
severity: warning
annotations:
summary: Host clock skew (instance {{ $labels.instance }})
description: "Clock skew detected. Clock is out of sync. Ensure NTP is configured correctly on this host.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostClockNotSynchronising
expr: '(min_over_time(node_timex_sync_status[1m]) == 0 and node_timex_maxerror_seconds >= 16) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host clock not synchronising (instance {{ $labels.instance }})
description: "Clock not synchronising. Ensure NTP is configured on this host.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRequiresReboot
expr: '(node_reboot_required > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 4h
labels:
severity: info
annotations:
summary: Host requires reboot (instance {{ $labels.instance }})
description: "{{ $labels.instance }} requires a reboot.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
_EOT
destination = "local/rules/node.yml"
left_delimiter = "{{{"
right_delimiter = "}}}"
}
template {
data = <<_EOT
@ -1411,6 +1056,362 @@ _EOT
right_delimiter = "}}}"
}
template {
data = <<_EOT
groups:
- name: NodeExporter
rules:
- alert: HostOutOfMemory
expr: '(node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host out of memory (instance {{ $labels.instance }})
description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostMemoryUnderMemoryPressure
expr: '(rate(node_vmstat_pgmajfault[1m]) > 1000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host memory under memory pressure (instance {{ $labels.instance }})
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostMemoryIsUnderutilized
expr: '(100 - (avg_over_time(node_memory_MemAvailable_bytes[30m]) / node_memory_MemTotal_bytes * 100) < 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 1w
labels:
severity: info
annotations:
summary: Host Memory is underutilized (instance {{ $labels.instance }})
description: "Node memory is < 20% for 1 week. Consider reducing memory space. (instance {{ $labels.instance }})\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualNetworkThroughputIn
expr: '(sum by (instance) (rate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual network throughput in (instance {{ $labels.instance }})
description: "Host network interfaces are probably receiving too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualNetworkThroughputOut
expr: '(sum by (instance) (rate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual network throughput out (instance {{ $labels.instance }})
description: "Host network interfaces are probably sending too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskReadRate
expr: '(sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual disk read rate (instance {{ $labels.instance }})
description: "Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskWriteRate
expr: '(sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write rate (instance {{ $labels.instance }})
description: "Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOutOfDiskSpace
expr: '((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host out of disk space (instance {{ $labels.instance }})
description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostDiskWillFillIn24Hours
expr: '((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host disk will fill in 24 hours (instance {{ $labels.instance }})
description: "Filesystem is predicted to run out of space within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOutOfInodes
expr: '(node_filesystem_files_free{fstype!="msdosfs"} / node_filesystem_files{fstype!="msdosfs"} * 100 < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host out of inodes (instance {{ $labels.instance }})
description: "Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostFilesystemDeviceError
expr: 'node_filesystem_device_error == 1'
for: 0m
labels:
severity: critical
annotations:
summary: Host filesystem device error (instance {{ $labels.instance }})
description: "{{ $labels.instance }}: Device error with the {{ $labels.mountpoint }} filesystem\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostInodesWillFillIn24Hours
expr: '(node_filesystem_files_free{fstype!="msdosfs"} / node_filesystem_files{fstype!="msdosfs"} * 100 < 10 and predict_linear(node_filesystem_files_free{fstype!="msdosfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly{fstype!="msdosfs"} == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host inodes will fill in 24 hours (instance {{ $labels.instance }})
description: "Filesystem is predicted to run out of inodes within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskReadLatency
expr: '(rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk read latency (instance {{ $labels.instance }})
description: "Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskWriteLatency
expr: '(rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 0.1 and rate(node_disk_writes_completed_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write latency (instance {{ $labels.instance }})
description: "Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostHighCpuLoad
expr: '(sum by (instance) (avg by (mode, instance) (rate(node_cpu_seconds_total{mode!="idle"}[2m]))) > 0.8) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 10m
labels:
severity: warning
annotations:
summary: Host high CPU load (instance {{ $labels.instance }})
description: "CPU load is > 80%\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# - alert: HostCpuIsUnderutilized
# expr: '(100 - (rate(node_cpu_seconds_total{mode="idle"}[30m]) * 100) < 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
# for: 1w
# labels:
# severity: info
# annotations:
# summary: Host CPU is underutilized (instance {{ $labels.instance }})
# description: "CPU load is < 20% for 1 week. Consider reducing the number of CPUs.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostCpuStealNoisyNeighbor
expr: '(avg by(instance) (rate(node_cpu_seconds_total{mode="steal"}[5m])) * 100 > 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host CPU steal noisy neighbor (instance {{ $labels.instance }})
description: "CPU steal is > 20%. A noisy neighbor is killing VM performances or a spot instance may be out of credit.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostCpuHighIowait
expr: '(avg by (instance) (rate(node_cpu_seconds_total{mode="iowait"}[5m])) * 100 > 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host CPU high iowait (instance {{ $labels.instance }})
description: "CPU iowait > 20%. A high iowait means that you are disk or network bound.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostUnusualDiskIo
expr: '(rate(node_disk_io_time_seconds_total[1m]) > 0.5) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host unusual disk IO (instance {{ $labels.instance }})
description: "Time spent in IO is too high on {{ $labels.instance }}. Check storage for issues.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostContextSwitching
expr: '((rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 20000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host context switching (instance {{ $labels.instance }})
description: "Context switching is growing on the node (> 20000 / CPU / s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
# - alert: HostSwapIsFillingUp
# expr: '((1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
# for: 2m
# labels:
# severity: warning
# annotations:
# summary: Host swap is filling up (instance {{ $labels.instance }})
# description: "Swap is filling up (>80%)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostSystemdServiceCrashed
expr: '(node_systemd_unit_state{state="failed"} == 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host systemd service crashed (instance {{ $labels.instance }})
description: "systemd service crashed\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostPhysicalComponentTooHot
expr: '((node_hwmon_temp_celsius * ignoring(label) group_left(instance, job, node, sensor) node_hwmon_sensor_label{label!="tctl"} > 75)) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host physical component too hot (instance {{ $labels.instance }})
description: "Physical hardware component too hot\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNodeOvertemperatureAlarm
expr: '(node_hwmon_temp_crit_alarm_celsius == 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: critical
annotations:
summary: Host node overtemperature alarm (instance {{ $labels.instance }})
description: "Physical node temperature alarm triggered\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRaidArrayGotInactive
expr: '(node_md_state{state="inactive"} > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: critical
annotations:
summary: Host RAID array got inactive (instance {{ $labels.instance }})
description: "RAID array {{ $labels.device }} is in a degraded state due to one or more disk failures. The number of spare drives is insufficient to fix the issue automatically.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRaidDiskFailure
expr: '(node_md_disks{state="failed"} > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host RAID disk failure (instance {{ $labels.instance }})
description: "At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostKernelVersionDeviations
expr: '(count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 6h
labels:
severity: warning
annotations:
summary: Host kernel version deviations (instance {{ $labels.instance }})
description: "Different kernel versions are running\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostOomKillDetected
expr: '(increase(node_vmstat_oom_kill[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host OOM kill detected (instance {{ $labels.instance }})
description: "OOM kill detected\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacCorrectableErrorsDetected
expr: '(increase(node_edac_correctable_errors_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: info
annotations:
summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacUncorrectableErrorsDetected
expr: '(node_edac_uncorrectable_errors_total > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 0m
labels:
severity: warning
annotations:
summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkReceiveErrors
expr: '(rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Receive Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} receive errors in the last two minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkTransmitErrors
expr: '(rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Transmit Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} transmit errors in the last two minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkInterfaceSaturated
expr: '((rate(node_network_receive_bytes_total{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"}[1m]) + rate(node_network_transmit_bytes_total{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"}[1m])) / node_network_speed_bytes{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"} > 0.8 < 10000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 1m
labels:
severity: warning
annotations:
summary: Host Network Interface Saturated (instance {{ $labels.instance }})
description: "The network interface \"{{ $labels.device }}\" on \"{{ $labels.instance }}\" is getting overloaded.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkBondDegraded
expr: '((node_bonding_active - node_bonding_slaves) != 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Bond Degraded (instance {{ $labels.instance }})
description: "Bond \"{{ $labels.device }}\" degraded on \"{{ $labels.instance }}\".\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostConntrackLimit
expr: '(node_nf_conntrack_entries / node_nf_conntrack_entries_limit > 0.8) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 5m
labels:
severity: warning
annotations:
summary: Host conntrack limit (instance {{ $labels.instance }})
description: "The number of conntrack is approaching limit\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostClockSkew
expr: '((node_timex_offset_seconds > 0.05 and deriv(node_timex_offset_seconds[5m]) >= 0) or (node_timex_offset_seconds < -0.05 and deriv(node_timex_offset_seconds[5m]) <= 0)) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 10m
labels:
severity: warning
annotations:
summary: Host clock skew (instance {{ $labels.instance }})
description: "Clock skew detected. Clock is out of sync. Ensure NTP is configured correctly on this host.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostClockNotSynchronising
expr: '(min_over_time(node_timex_sync_status[1m]) == 0 and node_timex_maxerror_seconds >= 16) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 2m
labels:
severity: warning
annotations:
summary: Host clock not synchronising (instance {{ $labels.instance }})
description: "Clock not synchronising. Ensure NTP is configured on this host.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostRequiresReboot
expr: '(node_reboot_required > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"}'
for: 4h
labels:
severity: info
annotations:
summary: Host requires reboot (instance {{ $labels.instance }})
description: "{{ $labels.instance }} requires a reboot.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
_EOT
destination = "local/rules/node.yml"
left_delimiter = "{{{"
right_delimiter = "}}}"
}
# A client cert, to connect to the AlertManager API
template {
data = <<_EOT

View File

@ -7,7 +7,7 @@ groups:
rules:
- alert: PrometheusTargetMissing
expr: up{job!~"sftp-PR\\d+"} == 0
expr: up == 0
for: 5m
labels:
severity: critical